Server Colocation
For clients that want the security and redundancy benefits of a Tier III data center, however do not want to have their servers in a shared cloud environment, RCN Networks offers dedicated and shared server colocation options using Coresite data center facilities. Colocating your equipment in a RCN Networks / Coresite Colocation facility gives you more than just state-of-the-art security and fail-safe provisions – you gain a direct connection to the nation's largest, NexGen fiber-optic network. Clients have the option to host dedicated physical servers in a private cloud owned and managed by RCN Networks, or by the client hosted in our facility with flexible power, bandwidth and space options available.
Service Details
- PowerChoices of AC or DC power per rack/cabinet
- SecurityMulti-layer security control procedures, biometric palm readers, and 24 x 7 closed-circuit video and alarm monitoring. Cabinets are 23" fully lockable mesh.
- CoolingHVAC redundant design with air distribution under raised flooring for maximum temperature control.
- Fire SuppressionSmoke detection system above and below raised floor; double-interlock, pre-action, dry-pipe fire suppression
- RacksAvailable at 19" or 23"
- Single 1U ColocationShared cabinet
- CagesAvailable with standard 10' x 10' and 10' x 20' dimensions
- Bulk spaceAvailable with 500 square feet minimum
Specifications
Certifications
- SSAE 16 Type 2
- Energy Star
Building Support
- Loading dock
- Exterior 48" dock-high with steel ramps
- Elevators
- Passenger: 7'w x 4'd x 9'h; 2,500 LBS
- Freight: 15'w x 9'd x 9'h; 10,000 LBS
- On-site parking
- 300 space open parking lot
- Storage and staging
- Private and shared areas
Corporate Amenities
- Office space and conference rooms
- 24x7x365 tech lounge with kitchen
Design Efficiency
- Electrical
- Mitsubishi high-efficiency UPS systems
- Power delivered from utility at high voltage to achieve rate reduction and distribution efficiencies
- Mechanical
- Variable speed CRAHs and ultrasonic humidification
- Life Safety
- Dual-interlock pre-action dry-pipe sprinkler system with VESDA
- Lighting
- Lutron Eco-System lighting
Space
- Facility size
- 273,000 square feet
- Deployments
- Cabinets, cages, private suites and build-to-suit
- Rooftop space available
- Power
- AC and DC
- Breakered and metered billing
- Fit out
- Powered shell, infrastructured shell, and turn-key
- Contract structure
- Colocation license or NNN lease
Security
- Key card access
- Biometric scanners
- Mantrap entries
- Perimeter and interior IP-DVR cameras
- 24x7x365 security guard monitoring
- 8' perimeter fence with controlled site access
Reliability
- Electrical
- NSTAR Power
- Diverse utility feeds
- N, N+1, 2N UPSs, PDUs, and RPPs; N+1 redundancy on generators
- 24 hours of on-site fuel storage
- Mechanical
- N+1 cooling towers, CRAHs, and chilled water pumps
- Staffing
- 24x7x365 on-site, BICSI and CFOT accredited personnel
- 24x7x365 remote hands
- BMS controls
- State-of-the-art mission critical controls and monitoring
- Uptime
- SLA of five 9s (99.999%)
- Six 9s (99.9999%) across portfolio for two years running
Structure
- Floor loading
- Floor 1: 250 LBS/SF
- Floor 2: 165 LBS/SF
- Column spacing
- 24' x 24'
- Clear height
- 9' above 36" raised floor
- Hardened exterior
- Roof designed to withstand 125 MPH wind speeds
- Reinforced interior cross-bracing